119 research outputs found

    Fire Safety Risk Analysis of a Health Care Facility

    Get PDF
    A methodology for deriving individual risk to people in a health care facility due to fire, is presented. The risk is expressed by the First Order Second Moment reliability index ß. The evacuation time for the patients is compared to the time to untenable conditions arise. Subjecting variables to uncertainty results in a reliability index value for the escape time margin. The influence on reliability index of various number of staff is examined. The scenarios are presented with the event tree methodology

    Study of movement on stairs during evacuation using video analysing techniques

    Get PDF

    BrandskyddsvÀrdering av flerbostadshus BSV-FB : Utveckling av metod för sÀkerhetsindex

    Get PDF
    A fire safety assessment method for multi-family buildings has been developed. The method is a scoring method and 19 parameters are assessed in order to determine the building fire safety level. Each parameter has its own weight for the total fire safety and the parameter weights are determined based on judgement in two expert groups. The expert groups have performed the weighting assessment independently. The method, BSV-FB, can be used by the building owner to compare the fire safety score with other building scores and make sure the building fire safety is not degraded

    BrandskyddsvÀrdering av vÄrdavdelningar - Ett riskanalysverktyg

    Get PDF
    I projektet har ett verktyg eller metod för bestÀmning av risk i vÄrdavdelningar tagits fram. Verktyget, BrandskyddsvÀrdering av vÄrdavdelningar (BSV-vÄrd) kan anvÀndas för att bestÀmma den relativa sÀkerheten för olika avdelningar vad avser brand. Meningen Àr att BSV-vÄrd skall kunna anvÀndas som ett komplement vid brandsyn. Verktyget kan ocksÄ tjÀna som checklista vid nyproduktion dÄ den ocksÄ ger information om hur viktiga olika faktorer Àr för brandskyddets upprÀtthÄllande. Men resultatet av metoden utgör inte automatiskt nÄgon garanti att brandskyddet Àr tillrÀckligt. Metoden Àr ett hjÀlpmedel som kan anvÀndas för att vÀrdera sÀkerheten. Metodiken bygger pÄ en multiattributmetod för beslutsfattande (Multiple Attribute Decision Making, MADM) vilket Àr en metod som framgÄngsrikt kombinerar kvantitativ och kvalitativ information. BSV-vÄrd Àr uppbyggd kring 26 olika komponenter som alla pÄ sitt sÀtt pÄverkar sÀkerheten vad avser brand pÄ en vÄrdavdelning. BÄde faktorer som höjer sÀkerheten och sÄdana som minskar sÀkerheten ingÄr. Dessa komponenter Àr olika betydelsefulla för sÀkerhetens upprÀtthÄllande och Àr dÄ ansatta med olika vikter. Ett högt viktvÀrde innebÀr att komponenten Àr betydelsefull för brandsÀkerheten. Exempel pÄ betydelsefulla komponenter Àr personal, lös inredning och drift och underhÄllsrutiner. PÄ varje avdelning bedöms sedan komponenterna utifrÄn de verkliga förhÄllandena. Beroende pÄ exempelvis personalens utbildningsnivÄ, antalet personal erhÄller komponenten ocksÄ en gradering. Denna fungerar ungefÀr som ett betyg. Med hjÀlp av graderingen och vikten för varje komponent kan den sammantagna bedömningen för avdelningen berÀknas, ett sÄ kallat brandskyddsindex (BSI). Detta sker genom Simple Additive Weighting vilket innebÀr att respektive produkt av vikt och gradering adderas till ett slutligt index avseende sÀkerheten. BÄde vikten och alternativen vid graderingen för varje komponent har bestÀmts genom ett bedömningsförfarande. Ett hierarkiskt system har anvÀnts för att bestÀmma de formella relationerna mellan de 26 komponenterna och högre liggande strategier och mÄlsÀttningarna för brandskydd. Den övergripande mÄlsÀttningen i BSV-vÄrd Àr att avdelningen skall ha tillfredsstÀllande brandsÀkerhet. Det Àr denna som brandskyddsindexet ger uttryck för. Bedömningsarbetet har skett genom diskussioner i tvÄ frÄn varandra isolerade grupper. Dessa har fÄtt ett grundmaterial att ta stÀllning till och utifrÄn detta gett synpunkter pÄ gradering och bedömt vikterna i det hierarkiska systemet. Syftet med att isolera grupperna frÄn varandra var att försöka eliminera eventuella dominerande medlemmar i gruppen sÄ att inte övriga deltagare alltför mycket pÄverkades av dessa. Detta verkar inte ha varit nÄgot större problem eftersom bÄda grupperna kommit till liknande stÄndpunkt. De har alltsÄ gjort liknande bedömningar. I en slutomgÄng sammanfördes bÄda gruppernas resultat till en gemensam bedömning. Denna gemensamma bedömning ligger till grund för de redovisade vÀrdena i metoden. BSV-vÄrd har utvÀrderats pÄ flera olika avdelningar. I denna utvÀrdering fick anvÀndarna, vilka inte tidigare var bekanta med metoden, göra en analys samt ocksÄ avge sin subjektiva bedömning av den allmÀnna sÀkerheten pÄ respektive avdelning. Denna bedömning ligger till grund för att kunna faststÀlla nÄgon form av nivÄ över vilken sÀkerheten kan anses vara acceptabel. Denna nivÄ baseras dock bara pÄ 17 analyser och skall ses som ett riktmÀrke. Vid en alternativ analys provades metoden pÄ en och samma avdelning men av flera anvÀndare. Syftet var att se pÄ olikheter i bedömningen nÀr förutsÀttningarna var desamma. Denna analys har gett vÀrdefull information för att öka robustheten vad avser olika tolkningar

    KartlÀggning och kvalitativ analys av möjligheter och risker med reducerad syrehalt i brandceller innehÄllande elektrisk utrustning

    Get PDF
    Fires can be an important hazard for the overall safe operation of nuclear power plants. Prevention of fire, fast detection and efficient extinguishment of a fire are some parameters, which are important to consider when designing the fire safety in a nuclear power plant. As an alternative to extinguishment system the use of hypoxic air or hypoxic air venting has been introduced e.g. in storage room of a museum or a historical building. This system is now being proposed for use in fire compartments in nuclear power plants containing electrical equipment such as electrical cabinets, cable trays, etc. This reports is a pre-study to investigate the risk and advantages of this system for use in these types of rooms. This report also stipulates a number of areas where more research or investigations are necessary. The results in this report are based on a literature review of scientific publications and specific technical standards available in the area in combination with the technical expertise of the authors. The report should not be seen as a final evaluation of hypoxic air venting systems

    Indoor Localization for Fire Safety : A brief overview of fundamentals, needs and requirements and applications

    Get PDF
    An indoor localization system for positioning evacuating people can be anticipated to increase the chances of a safe evacuation and effective rescue intervention in case of a tunnel fire. Such a system may utilize prevalent wireless technologies, e.g., Bluetooth, RFID and Wi-Fi, which today are used to survey incoming and outgoing traffic to a certain space or location, to estimate group sizes and to measure the duration of visits during normal operation of buildings. Examples also exist of where the same wireless technologies are used for safety purposes, for example to assess real-time location, tracking and monitoring of vehicles, personnel and equipment in mining environments. However, they are relatively few, and typically rely on a high degree of control over the people that are to be tracked, and their association with (connection to) the localization system used for the tracking. In this report, the results of a brief overview of the literature within the field of indoor localization in general, and the application of indoor localization systems within the field of particularly fire safety, is summarized. This information forms the underlying basis for the planning and execution of a future field study, in which an indoor Wi-Fi localization system will be tested and evaluated in terms of if, and if so how, it can be used to position evacuating people in tunnels. Whereas such a system allows digital footprints to be collected within a wireless network infrastructure (also already existing ones), questions remains to be answered regarding aspects such as precision and accuracy, and furthermore, how these aspects are affected by other independent variables. In the end of this report, examples of research questions deemed necessary to answer in order to enable a sound evaluation of the system is presented. These need to be addressed in the future planning of the above-mentioned field study

    Test av vÀgledande system i en tunnel

    Get PDF
    The report outlines the conditions and results of an evacuation experiments performed on 1-3 July 2014 in the Northern Link road tunnel in Stockholm. The aim was mainly to investigate how people can best be led to an opposite tunnel side during escape in a smoke-filled tunnel. The experiment also aimed to quantify the speed at which people move in smoke-filled tunnel environments (i.e. at reduced visibility conditions). Based on the analysis of the results from the experiment it can be concluded that the design of the escape portal, which was used during the experiment, seems to have fulfilled its purpose (getting people to use the emergency exits in smoke-filled tunnel environments). The most obvious result is that some form of guidance is required to get people walking along the right hand side to understand that they should change side at the height of the escape portal. At a minimum, information signs should be installed opposite the escape route to inform escaping persons that they are standing opposite an escape route. Several of the subjects also indicated that the evacuation signs with information about the distance to the nearest escape route were valuable. This was also stated by several of the people who were not exposed to this type of signs but as a suggestion to get a good evacuation environment. To further increase the likelihood that people evacuating from the Stockholm Bypass it is suggested that evacuation portals also should be equipped with active speakers. Several of the subjects who were exposed to this installation indicated that they benefited from it in finding the exit on the opposite side

    Utrymning genom tÀt rök: beteende och förflyttning

    Get PDF
    This report describes evacuation experiments, which were performed in a smoke filled tunnel. The tunnel was filled with artificial smoke and acetic acid was used to achieve irritation of the eyes and upper respiratory tract. In the experiments 46 persons walked through the tunnel one at a time, while they were filmed with infra red cameras. All participants answered a questionnaire and some were also interviewed. In the experiment different equipment was tested. The equipment included flashing lights at the emergency exits and directional guiding lights indicating the direction to an exit. In the report the relationship between walking speed and smoke density is presented and analysed. The participants ́ behaviour in the tunnel is also described and the important results from the questionnaires and interviews are presented. The report also includes a suggested alternative design of emergency exits

    Delrapport: Test av vÀgledande system i en tunnel

    Get PDF
    I följande delrapport redogörs övergripande för förutsĂ€ttningarna och delar av resultaten efter ett utrymningsförsök som genomfördes den 1-3 juli Ă„r 2014 i vĂ€gtunneln Norra lĂ€nken i Stockholm. Syftet med försöket var i huvudsak att undersöka hur personer pĂ„ bĂ€sta sĂ€tt kan ledas till en motstĂ„ende tunnelvĂ€gg med utrymningsvĂ€gar i en rökfylld tunnel. Försöket syftade Ă€ven till att kvantifiera med vilken hastighet mĂ€nniskor rör sig i rökfyllda tunnelmiljöer (d v s vid nedsatta siktförhĂ„llanden). Baserat pĂ„ en grov analys av de resultat som genererades under försöket kan det konstateras att designen av den utrymningsportal som anvĂ€ndes under försöket till stor del verkar ha uppfyllt sitt Ă€ndamĂ„l (att fĂ„ folk att anvĂ€nda nödutgĂ„ngar i rökfyllda tunnelmiljöer). Det mest pĂ„tagliga resultatet Ă€r att det krĂ€vs nĂ„gon form av vĂ€gledning för att personer som gĂ„r lĂ€ngs den högra sidan ska förstĂ„ att de ska byta sida i höjd med utrymningsportalen. Åtminstone bör informationsskyltar installeras mittemot utrymningsvĂ€garna för att upplysa utrymmande personer om att de befinner mittemot en utrymningsvĂ€g. Flera av försökspersonerna angav Ă€ven att de utrymningsskyltar med information om avstĂ„ndet till nĂ€rmaste utrymningsvĂ€g var vĂ€rdefulla. Det angav Ă€ven flera av de personer som inte exponerades för denna typ av vĂ€gledande markeringar men istĂ€llet som ett förslag för att fĂ„ en bra utrymningsmiljö. För att ytterligare öka sannolikheten att mĂ€nniskor vid en utrymning uppmĂ€rksammar och anvĂ€nder utrymningsvĂ€garna föreslĂ„s att utrymningsportalerna Ă€ven utrustas med aktiva högtalare. Flera av försökspersonerna som exponerades för denna installation uppgav att de hade nytta av den för att hitta utgĂ„ngen pĂ„ den motsatta sidan
    • 

    corecore